Garage and workshop electrics: how the supply gets there and what it needs.
A garage or workshop that is more than a place to park needs a permanent, protected supply, not an extension lead through the door. That normally means armoured cable from the house to a small consumer unit in the garage, with RCD protection and an earthing arrangement designed for a separate building.
Attached or detached?
An integral or attached garage can often be supplied by a circuit from the house, though it still needs RCD protection on its sockets. A detached garage needs a supply cable across the garden, usually steel wire armoured cable, buried or routed on a secure surface, to a small consumer unit inside. How it is earthed is a design decision your electrician has to make, because the earthing arrangement of the house may not be suitable to extend to an outbuilding.
What a good installation includes
| Item | Why |
|---|---|
| Armoured supply cable | Mechanically tough and suitable for outside runs, buried or surface-fixed. |
| Separate consumer unit | Local protection and a place to isolate the garage supply safely. |
| RCD protection | Modern rules expect RCD protection on sockets, and tools are used outside bodies of water, ladders and damp floors. |
| Earthing design | Often a TT earth rod arrangement for detached buildings, as the electrician judges. |
| Lighting | Enough LED lighting for safe working, on its own circuit if possible. |
| Sockets | Doubles at bench height and enough of them to stop trailing leads. |
Size the supply for what you will do
- Hobby tools and lighting: modest supply and a few sockets.
- Welders, compressors, large machine tools: may need a bigger supply, dedicated circuits and checks on the starting current. Tell the electrician what the machines are.
- Electric vehicle charging: a dedicated circuit and its own protection. See our EV charger service.
- Heating: a heater uses a lot of current and needs its own thought.
Safety extras
- Fit a smoke or heat alarm. Garages hold fuel, paint and flammable materials.
- Use sealed or IP-rated fittings where there is dust, damp or moisture.
- Keep sockets away from where water is used, and do not run extension leads across wet floors.
- Keep an escape route clear and fit an obvious isolator for the building.
Who does what
Running a new supply cable and fitting a consumer unit are notifiable and need a registered electrician. You can plan, dig your trench to a specification you have agreed, and tidy the space, but do not connect anything yourself.
Wiring that is already there
Garages often have old, unsupported supply cables, rusty light switches and one cracked socket on a spur from the house. If you inherit one, have it inspected before you plug in anything powerful. See EICR inspection.
Margate: coastal conditions
Garages near the seafront suffer from damp and salt, which corrode metal enclosures, hinges and terminals, so we suggest sealed fittings and corrosion-resistant boxes for any garage within a few hundred metres of the sea. See our salt-air guide for what to specify. In Old Town, garages and workshops are often tucked into narrow plots or converted outbuildings, so routing a cable can mean careful planning around neighbours' walls and boundaries. In conservation areas and listed properties, check before adding external trunking to visible walls. If the garage is going to be a home office or hobby room, our outbuilding power guide covers the same issues for non-garage buildings. Tell us what you plan to use it for and we will advise.
Lighting and layout tips
- Use bright, even LED lighting, with extra task lighting over the bench.
- Fit sockets at bench height and a few at low level for machines and chargers.
- Think about where doors swing so sockets are not blocked.
- Add a switch near the door so you can see before you enter.
- Consider emergency or exit lighting if the garage is attached and used for work.
Mistakes we see
- A single socket fed from the house by a thin cable run through a gap in the wall.
- A fused spur with a plug top fed to a garage fridge-freezer, with no protection against damp.
- Using household fittings in a damp, dusty or oily space.
- Storing petrol cans or paint next to a consumer unit or sockets.
- Extending the garage supply with extension leads along the floor.
Insurance and security
Check your home insurance cover for outbuildings and workshop contents, since some policies treat outbuildings differently. A good alarm and lighting also deter theft, and tools stored in a garage are an attractive target. If you run a business from the garage, check that your insurance and planning position allow it, and that the electrical installation is suitable for that use. A periodic inspection every few years is sensible for any workshop.
Plan for noise, dust and heat
Workshops create fine dust and heat, which shorten the life of cheap fittings. Choose sealed luminaires, keep sockets out of the dust path and avoid fitting the consumer unit directly above a bench or machine. If you spray paint, sand or cut metal, tell the electrician, because flammable vapour and sparks change which fittings are suitable.
Common questions
Can I power a garage with an extension lead?
Not as a permanent solution. A fixed supply with RCD protection is safer and complies with the wiring regulations. Extension leads through doors or windows are not a proper installation.
Does a detached garage need its own consumer unit?
Usually yes, fed by armoured cable from the house, with RCD protection and an earthing arrangement designed for the building.
Is garage wiring notifiable?
A new circuit is notifiable under Part P in England, so use a registered electrician who will certify and notify the work.
Need this done on your property?
Photos, postcode and a short description to hello@margateelectrical.co.uk or WhatsApp 07763 100 477. Same-day fixed quote.