Earthing and bonding explained for homeowners

Earthing gives a fault current a safe path back to the source so a breaker trips quickly. Bonding connects exposed metalwork, such as gas and water pipes, to earth so everything stays at nearly the same voltage. They work together, and both are checked in any inspection.

Two ideas, one goal

The three supply types

TypeHow the earth arrivesNotes
TN-SSeparate earth in the supply cable, often the lead sheath of an older cableCommon in older areas
TN-C-S (PME)Earth shared with the neutral, then split at the propertyVery common in newer supplies
TTAn earth electrode (a rod) in the ground, with no earth from the supplierMore common in rural settings. RCD protection is essential

Your electrician can tell which you have from testing, not by looking at the meter. The type matters for EV charger installations and for some outbuilding supplies, because TN-C-S has particular rules for external metalwork and vehicle connections.

What main protective bonding connects

Main bonding conductors are green-and-yellow cables, fixed with labelled clamps close to where the service enters the building:

  1. Metal gas pipe, near the meter, on the consumer's side.
  2. Metal water pipe, near the stop tap, where the incoming pipe is metal.
  3. Other incoming metal services, and in some cases oil pipes and structural metal.

Where the incoming water pipe is plastic, the bonding requirement can change, but metal pipes inside the house may still need attention. That judgement belongs to the electrician. The cable size depends on the supply type and the installation, so it is not a number to guess.

Supplementary bonding

Years ago, extra bonding was routinely fitted in bathrooms and kitchens. BS 7671 now allows it to be omitted where certain conditions are met, mainly RCD protection, correct main bonding and circuits with proper earth continuity. If you see bonding clamps around bathroom pipes, that is not wrong. If you do not, it may be perfectly acceptable.

What you can check yourself

Look, do not touch

Do not tighten, move or remove bonding clamps, and do not disconnect an earth to "stop a trip". Bonding and earthing connections are tested by an electrician, and removing one makes a shock more likely.

Where it goes wrong

Our companion guide, why your house needs earthing and bonding, explains what actually happens in a fault without them.

Margate local angle

Margate has a mix of older and newer supplies, so a house in the Old Town may have a different earthing arrangement from a post-war semi in Garlinge. Salt air increases corrosion at clamps, tails and terminals, so a bonding connection that was sound ten years ago can be loose today. If a house backs on to the sea front or the cliff, corrosion of exposed metal and connections is faster, which is why inspection and testing checks continuity rather than trusting appearances. Where an EV charger is planned, the supply type decides how the charger is earthed, so tell your installer early. See our EV charger page.

When earthing and bonding get checked

There are several moments when it is sensible to have the arrangements looked at. When a consumer unit is replaced, the earthing and bonding should be verified, because the new unit depends on them and the regulations expect it. When there has been plumbing or heating work, particularly replacement of metal pipes with plastic, ask for a check. When an EV charger or a solar and battery system is added, the earthing arrangements often influence the design. And in any periodic inspection, continuity of the earthing and bonding conductors is tested and recorded.

The results go on the certificate or report. Look for the type of earthing system, the size of the main earthing and bonding conductors, and any observations. If something is marked as a concern, ask the electrician to explain what it means for your house, not just what code it has been given.

Do not be alarmed by jargon. The principle is simple: a safe path for fault current, and no dangerous voltage between things you can touch.

Common questions

What is the difference between earthing and bonding?

Earthing gives fault current a path back to the supply so protective devices trip. Bonding connects metal services together and to earth so touchable metalwork stays at similar voltages.

How do I know what supply type I have?

An electrician can tell by testing at the origin of the installation. You cannot reliably tell by looking at the meter.

Do I need bonding on plastic pipes?

Plastic pipework changes the requirements, but metal parts inside the property may still need bonding. Ask your electrician to confirm after any plumbing work.