What is an AFDD and do you need one

An arc fault detection device (AFDD) is a breaker that listens for the electrical signature of dangerous arcing, such as a damaged cable or loose connection, and cuts the circuit before it starts a fire. They are recommended in some higher-risk situations, but they are not required in every home.

The problem an AFDD solves

Ordinary breakers deal with two things: overload and short circuit. An RCD deals with current leaking to earth. None of those reacts well to a small arc, for example a nail through a cable, a chewed flex, or a loose terminal that sparks with every vibration. Arcing generates intense local heat while drawing relatively little current, so a normal breaker may never trip. An AFDD monitors the waveform on the circuit and trips when the pattern looks like an arc.

What BS 7671 says

BS 7671:2018+A2:2022 recommends AFDDs in particular cases rather than for every dwelling. The recommendation points to single-phase socket circuits in higher-risk residential premises, such as houses in multiple occupation, student accommodation and care settings, and to locations with combustible construction materials or irreplaceable goods. For a typical family house, an AFDD is a good extra, not a requirement. The designer decides, and records why.

How they compare

DeviceProtects againstNotes
MCBOverload and short circuitNo shock protection
RCD / RCBOEarth leakage, shockAn RCBO also covers overload
AFDDArc faultsUsually combined with an RCBO, or paired with one

The downsides

Where they make most sense

  1. Multi-occupied buildings where a fire could trap sleeping people.
  2. Old timber-framed or lath-and-plaster buildings where fire spreads fast.
  3. Homes with older wiring that has not been replaced but has passed inspection.
  4. Properties where valuable or irreplaceable contents are stored.

Not a DIY swap

Fitting an AFDD means working inside the consumer unit. Only a registered electrician should do it, and the work must be tested and certified.

What you can do yourself

Nothing inside the board. You can, however, reduce the chance of arcing: do not trap flexes under furniture or doors, replace damaged plugs and leads, never use sockets that are cracked or burnt, and report buzzing, warm faceplates or a smell of burning. If your unit already has AFDDs, use the test button as the label says, and mention repeated trips on one circuit to your electrician.

Margate local angle

Margate has plenty of older and converted buildings where this question comes up. In Cliftonville, large Victorian and Edwardian houses and mansion blocks have been split into flats and bedsits over the decades, and some still operate as houses in multiple occupation, where the higher-risk recommendation is most relevant. In the Old Town, Georgian and older buildings with timber floors and long histories of alteration are exactly where hidden cable damage can sit unnoticed. If you are weighing up a rewire or a new unit in one of these, ask your electrician whether AFDDs on the socket circuits make sense for your building. See also our rewire service page.

Questions to ask before you pay for AFDDs

If your electrician proposes arc fault protection, it is reasonable to ask a few things. Which circuits will have it, and why those? Is the device combined with RCBO protection, or is a separate RCD still needed? How much room does the consumer unit have, and will the board need to be larger? What happens if a unit trips repeatedly: who investigates, and is that included?

It is also fair to ask about the alternative. For many houses, a well-installed board with RCBOs, an SPD and a clean inspection report gives a high level of protection already. Arc fault devices are an additional layer, and the benefit grows with the risk: sleeping accommodation, old fabric, combustible construction and hard-to-escape layouts.

Lastly, ask for the device make and model on the paperwork. If a unit needs replacing in future, you will want to match the board manufacturer's own parts rather than a mismatched device that was never tested in that enclosure.

If you already have an AFDD that trips, do not bypass it or swap it for an ordinary breaker. Note which circuit it protects and what was running, then ask your electrician to investigate. A genuine arc fault is exactly what the device is there to catch, and a cable with a damaged sheath or a scorched terminal is far better found now than after a fire. Keep any test results and the device documentation with your certificate.

Common questions

Do I need an AFDD in my house?

Not necessarily. BS 7671 Amendment 2 recommends them for certain higher-risk premises. For a normal family home it is a sensible option rather than a requirement. Your electrician will advise.

Can an AFDD replace an RCD?

No. They do different jobs. Many AFDD units are combined with RCBO protection in one device, but check what the unit actually provides before assuming it covers shock protection.

Why does my AFDD keep tripping?

Some appliances create electrical noise that can mimic an arc, but a repeat trip can also mean a real fault. Unplug items on that circuit and call an electrician if it keeps happening.